Page 54
Appendix | Industrial Process Interface (Optional)
thermoIMAGER TIM
Alarm: Relay open LED off
Normal: Relay closed LED on
Fail-safe status:
TIM Connect
Fig. 32 Example 2 for a fail-safe monitoring of the TIM with a PLC
Fail-safe monitoring states, see Fig. 32
[1] Malfunction of TIM
[2] Malfunction of TIM Connect software
[3] Breakdown of TIM power supply/ Interruption of USB cable
[4] Breakdown of PIF power supply
[5] Interruption of cable TIM-PIF
[6] Cable break of fail-safe cable
[7] Short circuit of fail-safe cable

Table of Contents