a. Interface specifications and voltage standards are different in different
countries. Please make sure that the relevant specifications of the
machine are consistent with the use specifications of electrical
appliances before use.
b. Do not connect any other AC power to the AC socket of the unit.
c. Do not plug the power cord input end of the unit into this AC socket.
d. AC output short circuit or load electrical power exceeding the AC
output power of the product will trigger the product to start short circuit
protection or over power protection. After eliminating short circuit or
removing the electrical equipment, please charge the product to restore
AC output function.
Note:
※
When this product is not used for power output, please timely press the
corresponding button or long-press the main power button for 2
seconds to turn off the output, so as to save energy.
Exception - LCD warning symbol
Charging fault (high and low
temperature protection)
Discharge high temperature
protection
DC or USB output fault
(overcurrent or short circuit
protection)
Flashing once per
second and go to
sleep after 10 seconds.
Flashing once per
second and will be
extinguished after
10 seconds.
AC output fault (overload or
short circuit protection)
PD output fault (overcurrent
or short circuit protection)
Unplug the charger and
reconnect it to charge when the
battery temperature returns to
normal.
After the battery temperature
returns to normal, press the
main power button to restore.
Press the DC button to restore
after the load is removed.
Press the AC button to restore
after the load is removed.
After the fault is removed,
re-plug and restore the output.