Special Notes:
For cold water use only.
Do not install where system will be exposed to direct sunlight.
Make certain that installation complies with all state and local laws and regulations.
The contaminants or other substances removed or reduced by the selected cartridge are
not necessarily in your water. Ask your local water municipality for a copy of their water
analysis, or have your water tested by a reputable water testing lab.
After prolonged periods of non-use it is recommended that the system be ushed
thoroughly. Let water run for 5–6 minutes before using.
The lter cartridges used with this system have a limited service life. Changes in taste,
odour, and/or ow of the water being ltered indicate that the cartridge should be
replaced.
Some harmless bacteria may attack cellulose media cartridges. If your cartridge
seems to disintegrate or develops musty or mouldy odour, switch to a synthetic media
cartridge or contact Davey for advice.
Please read all instructions, specications, and precautions before installing and using
this lter.
Installation:
Housings are easily installed on cold water lines. The water supply should be turned off at
the meter or, preferably, a shut off valve installed before (and after is also recommended)
the housing inlet to allow for easy installation/replacement of cartridges.
NOTE: When installing your housing allow a minimum of 2” (50mm) clearance below
housing bowl to enable lter cartridge changes. The lter housing connections are
standard female BSP (parallel) threaded ¾”, 1”, 1 ½” connections and can easily be
installed on copper, plastic or galvanised pipe by use of the appropriate ttings.
CAUTION: In some countries metal pipework is used as earth. If applicable in
your country, housings installed on metal pipelines must have a jumper wire
installed from the metal pipe on the inlet to the metal pipe on the outlet. This
work must be carried out by suitably qualied person.
WARNING: Do not over tighten inlet/outlet connections stripped threads
will result.
Pressure control and backow should be supplied and installed by a licensed practitioner.