3
Special Notes:
• For cold water use only.
• Do not install where system will be exposed to direct sunlight.
• Make certain that installation complies with all state and local laws and regulations.
• The contaminants or other substances removed or reduced by the selected cartridge are
not necessarily in your water. Ask your local water municipality for a copy of their water
analysis, or have your water tested by a reputable water testing lab.
• After prolonged periods of non-use it is recommended that the system be ushed
thoroughly. Let water run for 5–6 minutes before using.
• The lter cartridges used with this system have a limited service life. Changes in taste,
odour, and/or ow of the water being ltered indicate that the cartridge should be
replaced.
• Some harmless bacteria may attack cellulose media cartridges. If your cartridge
seems to disintegrate or develops musty or mouldy odour, switch to a synthetic media
cartridge or contact Davey for advice.
• Please read all instructions, specications, and precautions before installing and using
this lter.
Installation:
Housings are easily installed on cold water lines. The water supply should be turned off at
the meter or, preferably, a shut off valve installed before (and after is also recommended)
the housing inlet to allow for easy installation/replacement of cartridges.
NOTE: When installing your housing allow a minimum of 2” (50mm) clearance below
housing bowl to enable lter cartridge changes. The lter housing connections are
standard female BSP (parallel) threaded ¾”, 1”, 1 ½” connections and can easily be
installed on copper, plastic or galvanised pipe by use of the appropriate ttings.
CAUTION: In some countries metal pipework is used as earth. If applicable in
your country, housings installed on metal pipelines must have a jumper wire
installed from the metal pipe on the inlet to the metal pipe on the outlet. This
work must be carried out by suitably qualied person.
WARNING: Do not over tighten inlet/outlet connections – stripped threads
will result.
Pressure control and backow should be supplied and installed by a licensed practitioner.