EasyManua.ls Logo

Microlife WatchBP office User Manual

Microlife WatchBP office
39 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
EN
3
Simultaneous dual-arm
measurement and auscultatory
function for accurate office
blood pressure measurement.
Instruction Manual
ry

Questions and Answers:

Microlife WatchBP office Specifications

General IconGeneral
Device TypeUpper Arm Blood Pressure Monitor
Measurement MethodOscillometric
Display TypeLCD
Average ReadingYes
Irregular Heartbeat DetectionYes
PC ConnectivityUSB
Clinically ValidatedYes
Accuracy (Pressure)±3 mmHg
Accuracy (Pulse)±5% of reading
Measurement Range (Pulse)40 - 200 bpm
Cuff Size22 - 42 cm
Power Source4 x AA batteries
Dimensions150 x 100 x 50 mm

Summary

Product Description

Before Using WatchBP Office

Three Operation Modes Overview

Taking Measurements with WatchBP Office

Taking Measurements in AUSCULTATION Mode

Step-by-step guide for performing measurements in AUSCULTATION mode.

Taking Measurements in 1st VISIT Mode

Step-by-step guide for performing measurements in the 1st VISIT mode.

Taking Measurements in FOLLOW-UP Mode

Step-by-step guide for performing measurements in the FOLLOW-UP mode.

Viewing Measurement Results

Wireless Control Setup

Setting Up the Bluetooth Receiver

Guides users through installing the Bluetooth receiver driver on a computer.

Device Troubleshooting Guide

Troubleshooting: No Power or Display

Addresses issues related to the device not powering on or displaying anything.

Troubleshooting: Cuff Inflation Issues

Provides solutions for when the blood pressure cuff fails to inflate correctly.

Troubleshooting: Measurement Failure

Offers guidance when the device is unable to perform a blood pressure measurement.

Troubleshooting: Computer Connectivity Issues

Solves problems related to connecting or accessing the device from a computer.

Device Error Messages

Error Code Err 1: Signal Too Weak

Explains error code Err 1 and its cause related to weak pulse signals.

Error Code Err 2: Error Signal

Explains error code Err 2 and its cause related to detected error signals during measurement.

Error Code Err 3: No Cuff Pressure

Explains error code Err 3 regarding insufficient cuff pressure.

Error Code HI: High Pulse or Pressure

Explains error code HI for high pulse or cuff pressure.

Error Code Err 5: Abnormal Result

Explains error code Err 5 for inaccurate or unreadable measurement results.

Error Code LO: Low Pulse Rate

Explains error code LO for low pulse rate.

Safety, Care, Testing, and Disposal

Safety and Protection Guidelines

Provides essential safety guidelines for using the device correctly and preventing damage.

Related product manuals