Microlife BP A7 Touch
Europe / Middle-East / Africa
Microlife AG
Espenstrasse 139
9443 Widnau / Switzerland
Tel. +41 / 71 727 70 30
Fax +41 / 71 727 70 39
Email admin@microlife.ch
www.microlife.com
Asia
Microlife Corporation.
9F, 431, RuiGang Road, NeiHu
Taipei, 11492, Taiwan, R.O.C.
Tel. +886 2 8797-1288
Fax +886 2 8797-1283
Email service@microlife.com.tw
www.microlife.com
North / Central / South America
Microlife USA, Inc.
1617 Gulf to Bay Blvd., 2nd Floor Ste A
Clearwater, FL 33755 / USA
Tel. +1 727 442 5353
Fax +1 727 442 5377
Email msa@microlifeusa.com
www.microlife.com
IB BP A7 Touch E-V10 3716
EN 1
RU 10
BG 20
RO 30
CZ 38
SK 46
SL 54
SR 62
HU 70
HR 78

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Microlife BP A7 Touch and is the answer not in the manual?

Microlife BP A7 Touch Specifications

General IconGeneral
Device TypeUpper Arm Blood Pressure Monitor
Measurement MethodOscillometric
Display TypeLCD
Irregular Heartbeat DetectionYes
Atrial Fibrillation Detection (AFIB)Yes
MAM Technology (Microlife Average Mode)Yes
USB PortYes
Measurement Range - Pressure0-299 mmHg
Accuracy - Pressure±3 mmHg
Cuff Size22-42 cm
Memory200 readings
Measurement Range - Pulse40-180 beats per minute
Accuracy - Pulse+/- 5 % of reading
Power Supply4 x AA batteries or AC adapter

Summary

Important Facts about Blood Pressure and Self-Measurement

Important Facts about Atrial Fibrillation (AFIB)

Using the Device for the First Time

Battery Installation

Instructions for correctly inserting the batteries into the device.

Taking a Blood Pressure Measurement

Reliable Measurement Checklist

Essential pre-measurement steps for obtaining accurate blood pressure readings.

Battery Management

Error Messages and Troubleshooting

ERR 1: Signal Too Weak

Troubleshooting steps for weak signal errors during measurement.

ERR 2: Error Signal

Troubleshooting steps for errors caused by movement or tension.

ERR 3: No Pressure in Cuff

Troubleshooting steps for insufficient cuff pressure issues.

ERR 5: Abnormal Result

Troubleshooting steps for inaccurate or uninterpretable measurement results.

ERR 6: AFIB/MAM Mode Issues

Troubleshooting steps for errors specific to AFIB/MAM mode measurements.

Safety, Care, Accuracy, and Disposal

Safety and Protection

General safety precautions, handling advice, and environmental considerations.