Specification
NOTICE
Values do not include optional electric heat. See instructions for selected Heat Kit for specifications.
COOLING AND HEATING SPECIFICATIONS
SPECIFICATIONS
Series
18K 24K 30K 36K 48K 60K
Midea Indoor Unit Model: MVC- 18HWFN1-M 24HWFN1-M 30HWFN1-M 36HWFN1-M 48HWFN1-M 60HWFN1-M
Power supply
Rated
V, Ph, Hz
208/230V, 1, 60
MCA/MOCP
1
A 2.5 / 15.0 4.0 / 15.0 4.5 / 15.0 5.0 / 15.0 7.5 / 15.0 9.0 / 15.0
Indoor air flow
(Hi/Mi/Lo)
CFM
576.47/529.41/
488.24
758.82/694.12/
629.41
894.12/805.88/
711.76
1082.35/970.59/
864.71
1282.35/1094.12/
905.88
1582.35/1358.82/
1135.29
Indoor noise level
(Hi/Mi/Lo)
dB(A) 36/34/32 43/40.5/35 43/40/30.5 46.8/44/41.3 53/50/46 52.5/49/44
ESP
2
Range in WC 0-0.8 0-0.8 0-0.8 0-0.8 0-0.8 0-0.8
Throttle type EEV for cooling
Indoor unit
Dimension
(WxDxH)
in
21.02x17.52x45.00 21.02x17.52x45.00 21.02x21.02x49.02 21.02x21.02x49.02 21.02x21.02x49.02 21.02x24.49x52.99
Packing
(WxDxH)
in
25.20x20.87x50.39 25.20x20.87x50.39 25.20x24.41x54.33 25.20x24.41x54.33 25.20x24.41x54.33 25.20x27.76x58.27
Net/gross
weight
lbs 105.82/129.41 105.60/127.43 129.19/155.64 129.19/155.64 130.51/156.31 162.70/190.70
Refrigerant
piping
Liquid side/
gas side
in 3/8 / 3/4 3/8 / 3/4 3/8 / 3/4 3/8 / 3/4 3/8 / 3/4 3/8 / 7/8
Drainage water
pipe diameter
in 3/4 3/4 3/4 3/4 3/4 3/4
Communication protocol
between IDU and ODU
RS485+24V
Thermostat
type
Wireless remote
controller
Standard
Programmable
wired controller
Standard
Wi-Fi Optional
Qty per
20’/40’/40’ HQ
Indoor unit 39/82/154 39/82/154 27/57/57 27/57/57 27/57/57 27/57/57
• Air Handler
1
MCA: Minimum Circuit Ampacity / MOCP: Maximum Over Current Protection
2
External Static Pressure