DM16-01.01.07en Blanc On-off
Service manual 41
(3) Indoor fan can be set to high/med/low/auto.
(4) The louver operates the same as in cooling mode.
(5) Auto fan:
High
Low
Medium
10.4.2 Cooling Mode
10.4.2.1 Compressor running rules
When indoor room temp.T1 is lower than setting value, the compressor and outdoor fan will shut off.
T1
On
Off
10.4.2.2 Outdoor fan running rules
The On-off outdoor units have single fan speed. The outdoor fan will run following the compressor
except when AC is in evaporator high temp. protection in heating mode ,condenser high temp.
protection in cooling mode, defrosting mode and the current protection.
10.4.2.3 Indoor fan running rules
In cooling mode, indoor fan runs all the time and the speed can be selected as high, medium, low and
auto.
The auto fan: