11. Troubleshooting
11.1 Indoor Unit Error Display
Operation lamp Timer lamp Display LED STATUS
1 time
X E0 EEPROM parameter error
2 times
X E1
Indoor / outdoor units communication error(only for
MSMAD-24HRN1-QB8W)
3 times
X E2 Zero-crossing signal detection error
4 times
X E3 Indoor fan speed has been out of control
5 times
X E4
Indoor room temperature sensor T1 open circuit or
short circuit
6 times
X E5
Evaporator coil temperature sensor T2 open circuit or
short circuit
9 times
X E7 Indoor PCB /Display board communication error
7 times
X EC Refrigerant Leakage Detection
3 times
O F2
Condenser coil temperature sensor T3 or T4 open
circuit or short circuit(only for
MSMAD-24HRN1-QB8W)