Blanc On-off DM16-01.01.07en
54 Service manual
11.2.5 Open circuit or short circuit of temperature sensor diagnosis and solution (E4)
Error Code
E4/E5/F2
Malfunction decision
conditions
If the sampling voltage is lower than 0.06V or higher than 4.94V,
the LED will display the failure.
Supposed causes Wiring mistake
Sensor faulty
PCB faulty
Trouble shooting: