Installation
 Page 115 
3.  Indoor Unit Installation(A6 Duct 
type)
3.1  Service space for indoor unit
checking orifice
60cmX60cm
30cm or more
20cm or more
3.2  Hang Indoor Unit
1.Please refer to the following diagrams to locate the four 
positioning screw bolt hole on the ceiling. Be sure to mark 
the areas where ceiling hook holes will be drilled.
Air filter
Electric control box
L
M
Capacity(Btu/h)
Size of mounted plug
L
M
7k/9k/12k 741 360
18k 920 508
2. Install and fit pipes and wires after you have finished 
installing the main body. When choosing where to start, 
determine the direction of the pipes to be drawn out.
Especially in cases where there is a ceiling involved, align 
the refrigerant pipes, drain pipes, and indoor and outdoor 
lines with their connection points before mounting the 
unit..
3. Install hanging screw bolts.
1)   Cut off the roof beam.
2)  Strengthen the point at which the cut was made. 
Consolidate the roof beam..
4. After you select an installation location,align the 
refrigerant pipes, drain pipes, as well as indoor and 
outdoor wires with their connection points before 
mounting the unit..
5. Drill 4 holes 10cm (4”) deep at the ceiling hook 
positions in the internal ceiling. Be sure to hold the drill at 
a 90° angle to the ceiling.  
6. Secure the bolt using the included washers and nuts.
7. Install the four suspension bolts.
8. Mount the indoor unit with at least two people to 
lift and secure it. Insert suspension bolts into the unit’s 
hanging holes. Fasten them using the washers and nuts 
provided.
9. Mount the indoor unit onto the hanging screw bolts 
with a block. Position the indoor unit flat using a level 
indicator to prevent leaks.
Screw nut 
Washer
Hanging screw bolt
Overhang part
Shockproof cushion
Note: Confirm the minimum drain tilt is 1/100 or more.
3.3  Duct and accessories installation
1. Install the filter(optional) according to air inlet size.
2. Install the canvas tie-in between the body and duct.
3. The air inlet and air outlet duct should be far enough 
apart enough to a avoid air passage short-circuit.
4. Connect the duct according to the following diagram.
Canvas tie-in Canvas tie-in
Air outlet
Isolation booth
Isolation booth
checking orifice
Air inlet
Air dust filter