Midea Precision AC Technical Manual MCAC-PDSM-2013-01
92
The inverter power is too small.
Select a large power inverter.
E006
Inverter overheat error, the
temperature is higher than
90°C.
Ambient temperature is too high.
Check the ambient temperature.
Ventilation of inverter is not well.
Improve the ventilation environment.
Cooling fan error.
Check the cooling fan work or not.
Temperature detection circuit error.
Replace the detection.
E007 Soft start error
Soft start circuit or contactor is
damage.
Replace soft start.
E009
Output with lack of phase
error
Current of 3-phase output side is
asymmetric
Check the output connecting wire and
motor insulation.
E010 Out device error
Out error signal input terminal
activates.
Check the outer error reason.
The stop key is set to be
emergency stop.
Check the stop key.
E012
Current detection circuit
error
Current detecting components are
damaged.
Replace the detection.
E013 EEprom read and write error
Control panel components of
inverter are damaged.
Change the inverter
Outer disturb.
Find out disturb and
eliminate it.
E015 CPU disturb error Outer disturb
Find out disturb and eliminate it.
E030 Error alarm
This is an alarm; the inverter output
will not stop.
Press Esc key to exit the alarm status.