No. Name CN# Meaning
1 Power Supply
CN3 Earth: connect to Ground
CN1 N_in: connect to N-line (208-230V AC input)
CN2 L_in: connect to L-line (208-230V AC input)
2 S CN16 S: connect to indoor unit communication
3 HEAT1 CN17 connect to compressor heater, 208-230V AC when is ON
4 4-WAY CN60 connect to 4 way valve, 208-230V AC when is ON.
5 HEAT2 CN15 connect to chassis heater, 208-230V AC when is ON
6 AC-FAN CN25 connect to AC fan
7 TP T4 T3 CN22
connect to pipe temp. sensor T3, ambient temp. sensor T4, exhaust
temp. sensor TP
8 TP T4 T3 CN21
connect to pipe temp. sensor T3, ambient temp. sensor T4, exhaust
temp. sensor TP
9 PMV CN31 connect to Electric Expansion Valve
10 DC-FAN CN7 connect to DC fan
11 FAN_IPM IPM 501 IPM for DC fan
12 TESTPORT CN6 used for testing
13 EE_PORT CN505 EEPROM programer port
14 MCUPORT CN507 connect to PC communication
15
W CN28 connect to compressor
V CN29 0V AC (standby)
U CN30 10-200V AC (running)
16 COMP_IPM IPM 301 IPM for compressor
17 CN9 CN9 connect to reactor
18 CN32 CN32 connect to reactor
Note: This section is for reference only. Please take practicality as standard.