V4+R VRF 50/60Hz
201608 53
Part 5 - Diagnosis and Troubleshooting
4.3 E1 Troubleshooting
Digital display output 4.3.1
Description 4.3.2
Phase sequence error.
All units stop running.
Error code is only displayed on the unit with the error.
Possible causes 4.3.3
Power supply phases not connected in correct sequence.
Power supply terminals loose.
Power supply abnormal.
Main PCB damaged.