Table 7-1
Symptoms Causes Solution
Unit does not start
•  Power failure. 
•  Power switch is o.
•  Fuse of power switch may have burned. 
•  Batteries of remote controller exhausted 
or other problem of controller.
•  Wait for the comeback of power.
•  Switch on the power.
•  ReplLocation:
•  Replace the batterises or 
check the controller.
Air owing normally but 
completely can't cooling
•  Temperature is not set correctly. 
•  Be in 3 minutes protection of compressor.
•  Set the temperature properly. 
•  Wait.
Units start or stop frequently
•  Refrigerant is too little or too much. 
•  Air or no concreting gas in 
the refrigerating circuit.
•  Compressor is malfunction. 
•  Voltage is too high or too low. 
•  System circuit is blocked.
•  Check leakage, and rightly 
recharge refrigerant.
•  Vacuum and recharge refrigerant. 
•  Maintenance or change 
compressor. Install manostat.
•  Find reasons and solution.
Low cooling eect
•  Outdoor unit and indoor unit 
heat exchanger is dirty.
•  The air lter is dirty.
•  Inlet/outlet of indoor/outdoor 
units is blocked.
•  Doors and windows are open 
•  Sunlight directly shine.
•  Too much heat resource. 
•  Outdoor temp. is too high. 
•  Leakage of refrigerant or 
lack of refrigerant.
•  Clean the heat exchanger. 
•  Clean the air lter.
•  Eliminate all dirties and make air smooth.
•  Close doors and windows.
•  Make curtains in order to 
shelter from sunshine.
•  Reduce heat source.
•  AC cooling capacity reduces 
(normal). Check leakage and 
rightly recharge refrigerant.
Low heating eect
•  Outdoor temperature is lower than 7°C 
•  Doors and windows not 
completely closed.
•  Leakage of refrigerant or 
lack of refrigerant.
•  Use heating device.
•  Close doors and windows.
•  Check leakage and rightly 
recharge refrigerant.