R410A All DC Inverter Mini VRF MCAC-VTSM-2014-09
50 Specifications & Performance
MDV-V160W/DVN1
Heating
Combination
(%)
(Capacity
index)
Outdoor Air
temperature(°F)
Indoor temperature(°F WB)
60.8
64.4
68
69.8
71.6
75.2
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
°F DB
°F WB
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
70%
7.34
5
11.74
5.53
11.68
5.64
11.68
5.76
11.47
5.67
11.09
5.44
10.34
4.99
10.76
8.6
12.22
5.62
12.22
5.73
11.9
5.59
11.47
5.38
11.09
5.16
10.34
4.73
14.36
12.2
12.82
5.71
12.65
5.71
11.9
5.28
11.47
5.08
11.09
4.88
10.34
4.48
14.9
14
13.14
5.76
12.65
5.54
11.9
5.13
11.47
4.93
11.09
4.74
10.34
4.35
16.7
15.62
13.41
5.79
12.65
5.39
11.9
4.99
11.47
4.8
11.09
4.61
10.34
4.24
19.4
18.32
13.41
5.53
12.65
5.15
11.9
4.78
11.47
4.6
11.09
4.42
10.34
4.06
23
21.92
13.41
5.2
12.65
4.84
11.9
4.5
11.47
4.32
11.09
5.11
10.34
3.83
26.6
25.34
13.41
4.89
12.65
4.57
11.9
4.24
11.47
4.08
11.09
3.93
10.34
3.62
32
30.74
13.41
4.45
12.65
4.16
11.9
3.87
11.47
3.73
11.09
3.59
10.34
3.32
37.4
35.96
13.41
4.07
12.65
3.81
11.9
3.55
11.47
3.42
11.09
3.3
10.34
3.05
41
39.38
13.41
3.84
12.65
3.59
11.9
3.36
11.47
3.23
11.09
3.12
10.34
2.89
44.6
42.8
13.41
3.63
12.65
3.4
11.9
3.17
11.47
3.06
11.09
2.95
10.34
2.74
48.2
46.22
13.41
3.43
12.65
3.22
11.9
3
11.47
2.9
11.09
2.8
10.34
2.6
51.8
49.64
13.41
3.25
12.65
3.04
11.9
2.85
11.47
2.75
11.09
2.66
10.34
2.47
55.4
53.24
13.41
3.07
12.65
2.88
11.9
2.69
11.47
2.61
11.09
2.52
10.34
2.34
59
56.66
13.41
2.91
12.65
2.73
11.9
2.56
11.47
2.48
11.09
2.39
10.34
2.23
60%
7.34
5
11.5
5.67
10.85
5.28
10.2
4.89
9.88
4.71
9.55
4.52
8.9
4.16
10.76
8.6
11.5
5.37
10.85
5
10.2
4.64
9.88
4.47
9.55
4.29
8.9
3.97
14.36
12.2
11.5
5.07
10.85
4.73
10.2
4.39
9.88
4.22
9.55
4.06
8.9
3.75
14.9
14
11.5
4.93
10.85
4.6
10.2
4.27
9.88
4.11
9.55
3.95
8.9
3.64
16.7
15.62
11.5
4.8
10.85
4.48
10.2
4.16
9.88
4.01
9.55
3.85
8.9
3.56
19.4
18.32
11.5
4.59
10.85
4.29
10.2
3.98
9.88
3.84
9.55
3.69
8.9
3.41
23
21.92
11.5
4.32
10.85
4.04
10.2
3.76
9.88
3.62
9.55
3.49
8.9
3.23
26.6
25.34
11.5
4.08
10.85
3.82
10.2
3.56
9.88
3.43
9.55
3.3
8.9
3.05
32
30.74
11.5
3.73
10.85
3.49
10.2
3.26
9.88
3.15
9.55
3.03
8.9
2.81
37.4
35.96
11.5
3.42
10.85
3.21
10.2
3
9.88
2.89
9.55
2.79
8.9
2.59
41
39.38
11.5
3.23
10.85
3.04
10.2
2.84
9.88
2.74
9.55
2.65
8.9
2.46
44.6
42.8
11.5
3.06
10.85
2.87
10.2
2.69
9.88
2.6
9.55
2.51
8.9
2.34
48.2
46.22
11.5
2.9
10.85
2.73
10.2
2.55
9.88
2.47
9.55
2.38
8.9
2.22
51.8
49.64
11.5
2.75
10.85
2.59
10.2
2.43
9.88
2.35
9.55
2.27
8.9
2.12
55.4
53.24
11.5
2.6
10.85
2.45
10.2
2.3
9.88
2.23
9.55
2.16
8.9
2.01
59
56.66
11.5
2.48
10.85
2.33
10.2
2.19
9.88
2.12
9.55
2.06
8.9
1.92
50%
7.34
5
9.58
4.55
9.04
4.24
8.5
3.95
8.18
3.8
7.91
3.66
7.37
3.38
10.76
8.6
9.58
4.32
9.04
4.03
8.5
3.75
8.18
3.62
7.91
3.48
7.37
3.22
14.36
12.2
9.58
4.09
9.04
3.82
8.5
3.56
8.18
3.43
7.91
3.31
7.37
3.06
14.9
14
9.58
3.98
9.04
3.72
8.5
3.47
8.18
3.34
7.91
3.22
7.37
2.98
16.7
15.62
9.58
3.88
9.04
3.63
8.5
3.38
8.18
3.26
7.91
3.15
7.37
2.91
19.4
18.32
9.58
3.72
9.04
3.48
8.5
3.25
8.18
3.13
7.91
3.02
7.37
2.8
23
21.92
9.58
3.51
9.04
3.29
8.5
3.07
8.18
2.97
7.91
2.86
7.37
2.65
26.6
25.34
9.58
3.32
9.04
3.12
8.5
2.91
8.18
2.81
7.91
2.71
7.37
2.52
32
30.74
9.58
3.05
9.04
2.86
8.5
2.68
8.18
2.59
7.91
2.5
7.37
2.33
37.4
35.96
9.58
2.81
9.04
2.64
8.5
2.47
8.18
2.39
7.91
2.31
7.37
2.16
41
39.38
9.58
2.66
9.04
2.5
8.5
2.35
8.18
2.27
7.91
2.2
7.37
2.05
44.6
42.8
9.58
2.53
9.04
2.38
8.5
2.24
8.18
2.16
7.91
2.09
7.37
1.96
48.2
46.22
9.58
2.4
9.04
2.26
8.5
2.12
8.18
2.06
7.91
1.99
7.37
1.86
51.8
49.64
9.58
2.28
9.04
2.15
8.5
2.03
8.18
1.96
7.91
1.9
7.37
1.78
55.4
53.24
9.58
2.17
9.04
2.04
8.5
1.93
8.18
1.87
7.91
1.81
7.37
1.7
59
56.66
9.58
2.06
9.04
1.95
8.5
1.84
8.18
1.78
7.91
1.73
7.37
1.62
Note:
1. is tested under our standard condition.
2. Avoid to run the unit when the temperature is below 5 (-15).
3. The above table shows the average value of conditions may operate.
4. It is recommended to connect less than 130%.