8
Safety Precautions
 WARNING
•  Be sure to disconnect the power supply before 
working on the unit. 
•  All electrical wiring must be done according to  
local and national regulations. 
•  Electrical wiring must be done by a qualified   
technician. Improper connections may cause 
electrical malfunction, injury and fire. 
•  An independent circuit and single outlet must 
 
•  Connect the power cable to the terminals and 
 
fasten it with a clamp. An insecure connection
may cause fire.  
•  Make sure that all wiring is done correctly and the 
control board cover is properly installed. Failure 
to do so can cause overheating at the connection 
points, fire, and electrical shock.  
•  Ensure that main supply connection is made 
through a switch that disconnects all poles, with 
 CAUTION
•  Connect the outdoor wires before connecting the 
indoor wires.
•  Make sure you ground the unit. The grounding 
wire should be away from gas pipes, water pipes, 
lightning rods, telephone or other grounding 
wires. Improper grounding may cause electrical 
shock.    
•  DO NOT  connect the unit with the power source 
until all wiring and piping is completed.
•  Make sure that you do not cross your electrical 
wiring with your signal wiring, as this can cause 
distortion and interference.  
Follow these instructions to prevent distortion when the 
compressor starts: 
•  The unit must be connected to the main outlet. 
Normally, the power supply must have a low output 
impedance of 32 ohms.  
•  No other equipment should be connected to the  
same power circuit.
•  The unit’s power information can be found on the 
Outdoor Unit Wiring
 WARNING
Before performing any electrical or wiring work, turn off 
the main power to the system. 
1.  Prepare the cable for connection
Rated Current of   
Appliance (A)
Nominal Cross-Sectional 
Area (mm²)
 6 0.75
6 - 10 1
10 - 16 1.5
16 - 25 2.5
25- 32 4
32 - 45 6
Wiring
contact gap of a least 3mm. 
Wiring
 
 
be used for this unit.   If the 
electrical circuit capacity is not enough or there 
is a defect in the electrical work, it can lead to 
shock, fire, unit and property damage.     
 Page 20  
NOTE: The fuse is made of ceramic. 
 
rating sticker on the product.