Website: www.mideaaircon.com
Service manual
CAUTION
- BEFORE SERVICING THE UNIT, READ THE SAFETY
- PRECAUTIONS IN THIS MANUAL.
- ONLY FOR AUTHORIZED SERVICE PERSONNEL.
MODELS:
MPK-09CEN2 MPK-09CRN2 MPK-09EEN2 MPK-09ERN2
MPK-10CEN2 MPK-10CRN2 MPK-10EEN2 MPK-10ERN2
MPK-12CEN2 MPK-12CRN2 MPK-12EEN2 MPK-12ERN2
MPK-08CE MPK-08CR MPK-08EE MPK-08ER
MPK-09CE MPK-09CR MPK-09EE MPK-09ER
MPK-10CE MPK-10CR MPK-10EE MPK-10ER
MPK2-09CEN1-QB6 MPK2-09CRN1-QB6 MPK2-09EEN1-QB6 MPK2-09ERN1-QB6
MPK2-10CEN1-QB6 MPK2-10CRN1-QB6 MPK2-10EEN1-QB6 MPK2-10ERN1-QB6
MPK2-12CEN1-QB4 MPK2-12CRN1-QB4 MPK2-12EEN1-QB4 MPK2-12ERN1-QB4

Questions and Answers

  • M
    Matthew JordanAug 19, 2025
    Why is my Midea MPK2-12ERN1-QB4 Air Conditioner not cooling or heating?
    • B
      Beth PageAug 19, 2025
      If your Midea Air Conditioner isn't cooling or heating, begin by checking the voltage. Verify the wiring terminals are secure, repairing them if loose. Ensure the temperature and mode settings are correctly adjusted. Inspect the compressor, overload protector, and wiring for any damage, replacing if necessary. If the unit uses an electric heater, check for damage and replace if needed. Also, examine the overheat fuse and replace if it's damaged. Finally, check the voltage of the main PCB; if the unit fails in heating mode, replace the main PCB.
  • C
    Catherine LawsonAug 21, 2025
    How to fix no power display on panel of Midea Air Conditioner?
    • T
      Todd SnyderAug 22, 2025
      If there is no power display on the panel or button failure on your Midea Air Conditioner, check the power supply to ensure it's providing power to the unit. Inspect the power cord for damage and correct if necessary. Check the resistance between the input/output lines on the transformer (discharge transformer before testing), and replace the transformer if either input/output is open or the transformer is damaged. Check the voltage on the display board, replace the display board if it is +5V else replace the main PCB.
  • H
    Haley SheppardAug 25, 2025
    What to do if Midea Air Conditioner shows water full alarm?
    • T
      Timothy WoodsAug 26, 2025
      If you're getting a water full alarm on your Midea Air Conditioner, start by checking if the water tank is full and empty it if necessary. Inspect the water depth sensor and replace it if it has failed. Check the water pump and replace it if it's not working. If the water depth is overloaded in the chassis, drain the water by opening the drainage hose. Finally, inspect the water depth sensing structure and replace or realign it if it's faulty.
  • E
    Eugene GarnerAug 28, 2025
    How to fix Midea MPK2-12ERN1-QB4 fan motor noise?
    • L
      lisa09Aug 28, 2025
      If your Midea Air Conditioner's fan motor is making noise, the fan blower might be cracked, out of balance, or partially missing; replace it if any of these issues are present. Check for any loose screws and tighten them. If knocking sounds continue when the motor is running, or if the motor hums or the noise appears internal, the bearings may be worn; replace the motor in this case.
  • S
    Scott SilvaAug 31, 2025
    What to do if compressor will not run while fan motor runs in Midea MPK2-12ERN1-QB4 Air Conditioner?
    • J
      Johnny ThomasAug 31, 2025
      If the fan motor runs but the compressor won't start on your Midea Air Conditioner, start by checking the voltage. Inspect the wire connections and repair or replace any loose terminals. If wires are off, refer to the wiring diagram for proper placement. Check the voltage of the main PCB and replace it if open. Examine the capacitor and replace it if it's not within +/-10% of the manufacturer's rating or if it's shorted, open, or damaged. Ensure the room temperature setting is at the coolest setting in cooling mode or the warmest in heating mode. Finally, check the compressor for open circuits or grounding, and replace the compressor if necessary.
  • H
    harrisonsandraSep 6, 2025
    Why does my Midea MPK2-12ERN1-QB4 Air Conditioner unit start and stop frequently?
    • J
      Joseph SchwartzSep 6, 2025
      If your Midea Air Conditioner starts and stops frequently, the input power supply voltage may be too low. Check the voltage and call an electrician if it's not within limits. Inspect the main PCB and replace it if the compressor relay on the PCB is shorted or damaged. Also, when the room temperature is too high, the compressor will protect itself.
  • H
    heidi64Sep 9, 2025
    Why does Midea MPK2-12ERN1-QB4 Air Conditioner compressor stop instantly after startup?
    • M
      Michelle WatkinsSep 9, 2025
      If the compressor on your Midea Air Conditioner stops instantly after startup, it could be due to too much refrigerant, causing the compressor load to be too high. Recycle and recharge the refrigerant after checking for the reason. Alternatively, the compressor might be blocked internally; replace it after investigating the cause.
  • E
    Elizabeth ClarkSep 12, 2025
    Why does Midea MPK2-12ERN1-QB4 Air Conditioner fan motor run intermittently?
    • R
      robertcooleySep 12, 2025
      If the fan motor on your Midea Air Conditioner runs intermittently, it may be cycling on overload. Check the voltage, and if it's not within limits, call an electrician. Test the capacitor and replace it if it's not within +/-10% of the manufacturer's rating. Check the bearings; if the blower wheel cannot rotate freely, replace the motor. If the speed does not change from high speed to low speed, replace the motor.
  • R
    Ronald TrujilloNov 15, 2025
    Why is my Midea MPK2-12ERN1-QB4 Air Conditioner cooling or heating not good?
    • S
      Steven TerryNov 15, 2025
      If your Midea Air Conditioner isn't cooling or heating well, several factors could be the reason. Start by checking the air filter and cleaning or replacing it if it's restricted. Ensure the air discharge pipe is properly aligned and not damaged. Make sure the unit is appropriately sized for the room. Clean the condenser and evaporator coils if they are restricted. Inspect the water showering system for blockages and clean if necessary. Check the fan capacitor and replace if it's outside +/-10% of the manufacturer's rating. Clear any obstructions blocking airflow to the unit. If there is less refrigerant, check the tubes for leaks, repair them, and recharge the refrigerant. Regulate the flow of the capillary tube if the evaporator is frosted, replace if blocked, and repair any leaks. If th...

Summary

1. Preface and Safety

1.1 Safety Precautions

Essential safety guidelines for servicing and operating the unit.

1.2 Insulation Resistance Test

Procedure for ensuring electrical safety through insulation testing.

1.3 Unit Features

Overview of the key functionalities and characteristics of the air conditioner.

1.4 Control Locations Overview

Identifies the locations of controls on the unit.

2. Troubleshooting and Electrical Functions

2.1 Refrigeration Cycle Diagram

Diagram illustrating the unit's refrigeration cycle for diagnostic purposes.

2.2 Electrical Function Details

Covers working environment, symbols, systematic functions, protection, and operational modes.

2.3 Troubleshooting Common Problems

Guide to identifying and resolving common operational problems with causes and remedies.

3. Wiring Diagrams and Schematics

3.1 Cooling Only Models Wiring

Wiring diagrams specific to cooling-only models.

3.2 Cooling and Heating Models Wiring

Wiring diagrams for cooling and heating models.

3.3 Electrical Control Scheme

Detailed electrical control schematic diagram.

4. Unit Disassembly and Component Replacement

4.1 Unit Preparation and Panel Removal

Steps to prepare the unit and remove rear/front panels.

4.3 Display Board Assembly Removal

Steps to disassemble the display board assembly.

4.5 Main Control Board Replacement

Procedure for replacing the main control board.

4.7 Evaporator Fan Motor and Heater Replacement

Steps to replace the evaporator fan motor or electric heater.

4.8 Condenser Fan Motor Replacement

Instructions for replacing the condenser fan motor.

4.9 Refrigerant System and Compressor Service

Procedure for repairing the refrigerant system or replacing the compressor.

4.10 Water Disposal System Service

Steps to repair water disposal system or replace pump/switch.

5. Exploded View, Parts List, and Specifications

5.1 Exploded View

Visual representation of the unit's components for identification.

5.2 Spare Parts List

List of available spare parts for the unit.

5.3 Specifications

Technical specifications of the unit.

Midea MPK2-12ERN1-QB4 Specifications

General IconGeneral
ModelMPK2-12ERN1-QB4
BrandMidea
CategoryAir Conditioner
Cooling Capacity12000 BTU/h
RefrigerantR410A
Operating Voltage220-240V
Operating Frequency50Hz
FeaturesSleep Mode, Remote Control, Timer