Electronic function
20
8.9 Heating mode
8.9.1
8.9.2 At heating mode, the setting temperature range is 17’C~30’C. (62’F~88’F)
8.9.3 At heating mode, the action of the electric heater:
8.9.4 The inner fan speed can by select at heating mode----Auto, low, middle, and high. The
outer fan is off and compressor is off at heating mode.
8.9.5 Auto wind at heating mode.
8.9.5.1 The fan motor is decided by the temperature different between TA and TS.
8.9.5.2 If the fan motor is at low speed, and TA-TS-1’C, the fan motor turn to middle fan and
continue running 1 minute at least.
8.9.5.3 If the fan motor is at middle speed, and TATS-1°C, the fan motor turn to high fan and
continue running 1 minute at least.
8.9.5.4 If the fan motor is at middle speed, and TA=TS, the fan motor maintain the middle fan
and continue running 1 minute at least.
8.9.5.5 If the fan motor is at middle speed, and TATS1°C, the fan motor turn to low fan and
continue running 1 minute at least.
8.9.6 The ionizer and timer are available at heating mode.