14 
 
  7.5.2.1    If TA﹥TS+1℃, the two fans operate. After 15 seconds, the compressor operates. 
7.5.2.2    If TA≤TS after the compressor operates, this compressor will stop, and two fans last for working 
all the time. 
7.5.3 Auto fan acts as below rules: 
 
 
 
 
 
 
 
 
7.5.5. The TIMER function is valid in the cooling mode. 
 
7.6 Drying mode 
7.6.1.  When  the  unit  starts  to  operate  at  drying  mode,  the  compressor  will  start  while  the  room 
temperature is over 13℃. After the compressor started, the compressor will operate as below. 
 
TA  
℃
15
13
Compressor on
Operation conditon  
Compressor off
 
 
7.6.1.1 When TA<13℃, the compressor stops. And the fan operates at low speed at all time. 
7.6.1.2 When TA≥14℃, the compressor operates. 
7.6.2. The fan operates with compressor.   
 
 
 
 
14
13