DM16‐01.01.27en RooftopClimaCreatorseries
46 Service manual
5. Performance data
MRCT-062CWN1-R(C)
Cooling capacity:
Gross Cooling Capacity
Ambient DB(°C) 29.4 35
Indoor WB(°C) 16.1 19.4 22.8 16.1 19.4 22.8
CFM DB(°C) TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI
2,000
23.9 65.4 57.1 5614.7 75.8 42.6 6170.5 79.0 26.7 7560.1 62.1 54.5 5930.5 68.0 41.2 6189.5 78.4 25.8 7970.3
26.7 66.8 63.6 5758.7 77.4 53.8 6345.5 80.7 38.8 7760.1 63.5 59.6 6274.9 69.5 52.9 6534.0 80.0 38.1 8220.3
29.4 68.2 67.8 6011.6 79.0 64.8 6783.1 82.4 48.1 8110.1 64.8 61.6 6705.8 71.0 64.6 6970.9 81.7 48.3 8728.0
32.2 69.6 69.6 6299.6 80.7 75.4 7133.1 84.1 56.9 8504.1 66.2 64.5 6999.8 72.4 68.5 7302.8 83.4 58.6 9128.0
2,800
23.9 69.5 61.1 5904.0 76.7 44.7 6236.8 79.5 27.2 7596.3 64.1 56.8 6219.8 69.3 43.2 6255.8 78.8 26.2 8000.4
26.7 70.9 66.9 6048.0 78.4 57.0 6411.8 81.2 38.5 7796.3 65.5 62.1 6564.2 75.0 56.1 6600.3 80.5 38.9 8250.4
29.4 72.4 70.2 6313.0 80.0 67.9 6855.4 82.9 48.3 8146.3 66.9 64.3 7007.2 77.3 68.8 7043.2 82.2 49.8 8758.1
32.2 74.0 72.7 6606.9 81.7 77.1 7205.4 84.6 59.1 8540.3 68.4 67.8 7307.2 78.5 72.9 7375.1 83.9 61.0 9158.1
3,600
23.9 71.2 65.0 6024.5 77.4 45.9 6285.0 79.7 27.6 7608.3 66.1 59.2 6340.3 72.9 45.3 6515.0 79.1 26.7 8024.5
26.7 72.7 67.1 6174.5 79.0 58.0 6460.0 81.4 42.0 7808.3 67.5 62.7 6690.8 77.1 59.1 6740.0 80.8 39.6 8274.5
29.4 74.2 70.0 6439.5 80.7 70.2 6903.6 83.1 49.2 8158.3 69.0 66.3 7133.7 78.6 72.4 7133.6 82.5 51.1 8782.3
32.2 75.8 73.7 6739.5 82.4 80.3 7253.6 84.9 59.4 8558.3 70.4 69.0 7439.8 80.0 73.4 7483.6 84.2 62.6 9182.3
Notes:
1. All capacities are gross and have not considered indoor fan heat. To obtain net cooling capacity subtract indoor fan heat;
2. TC = Total Capacity (Unit: 1,000Btu/h); SC = Sensible Capacity (Unit: 1,000Btu/h).