EasyManua.ls Logo

Midea MS9A-05CR-QD0

Midea MS9A-05CR-QD0
61 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
48
8.4.3.5 High evaporator coil temp.T2 protection:
8.4.4 Auto-mode
The machine will choose cooling, heating or fan-only mode according to ΔT (ΔT =T1-Ts).
For MS9A-09CR-QC4(A), MS9A-12CR-QC4(A), MS9A-18CR-QC0 models:
ΔT=T1-Ts Running mode
ΔT2
Cooling
-3≤ΔT≤2
Fan-only
ΔT<-3
Heating
(for cooling only models, they will run at
fan-only mode)
For other models:
ΔT=T1-Ts Running mode
ΔT2
Cooling
-1≤ΔT≤2 Fan-only
ΔT<-1 Heating
(for cooling only models, they
will run at
fan-only mode)
AC will run in auto mode in the below cases:
1 Press the forced auto button.
2 If AC is off, it will run in auto mode when timer on function is active.
3 After setting the mode, AC will run in auto mode if the compressor keeps not running for 15
minutes(20 minutes for MS9A-09CR-QC4(A), MS9A-12CR-QC4(A), MS9A-18CR-PC4W(A),
MS9A-18CR-QB8,
MS9A-18CR-QC0,
MS9A-18CR-QC0(A), MS9A-18CR-QC2, MS9A-18CR-QC4(A),
MS9A-22CR-QC0,
MS9A-22CR-QB8).
8.4.5 Drying mode

Related product manuals