29
After AC starts up, the compressor will run at the Fmax frequency for 7 minutes according to outdoor
ambient temp. During the 7 minutes, frequency limitation is active.
7 minutes later, compressor running frequency will be controlled as below:
While
Temp. zone
A
B
C
D
E
F
G
H
Frequency
F10
F9
F8
F7
F5
F3
F1
F0
ΔT=0 a s d efa u lt.