EasyManuals Logo

Midea MSE-09CR User Manual

Midea MSE-09CR
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #28 background imageLoading...
Page #28 background image
Service manual
25
§
9. Pressure table
Note:
The pressure data is from 3 way valve, the pressure data are pressure above atmosphere.
D: Dry bulb temp.
W: Wet bulb temp.
9.1 MSE-07CR
Indoor
Conditions
Pressure
25ºC 30ºC 35ºC 40ºC 45ºC 50ºC
21ºC D
Pressure
15ºC W
(kg/cm
2
)
24ºC D
Pressure
17ºC W
(kg/cm
2
)
27ºC D
Pressure
19ºC W
(kg/cm
2
)
32ºC D
Pressure
23ºC W
(kg/cm
2
)
4.8 4.9
Cooling mode
Outdoor temperature (Dry bulb temp)
4.2 4.4 4.5 4.6 4.7 4.9
5 5.1
4.9 5 5.1 5.2 5.4 5.5
4.5 4.6
6 6.25 5.1 5.5 5.8
9.2 MSE-07HR
Indoor
Conditions
Pressure
25ºC 30ºC 35ºC 40ºC 45ºC 50ºC
21ºC D
Pressure
15ºC W
(kg/cm
2
)
24ºC D
Pressure
17ºC W
(kg/cm
2
)
27ºC D
Pressure
19ºC W
(kg/cm
2
)
32ºC D
Pressure
23ºC W
(kg/cm
2
)
4.8 4.9
Cooling mode
Outdoor temperature (Dry bulb temp)
4.2 4.4 4.5 4.6 4.7 4.9
5 5.1
4.9 5 5.1 5.2 5.4 5.5
4.5 4.6
6 6.25 5.1 5.5 5.8
7ºC D
-7ºC D
-15ºC D
6ºC W
-9ºC W
-xºC W
Pressure
(kg/cm
2
)
Pressure
(kg/cm
2
)
Pressure
(kg/cm
2
)
Pressure
(kg/cm
2
)
19 18.2 /
22ºC 24.57 22.1 20.9 19.8 19.1 /
20ºC 23.4 21 20.1
17.1 16.3 /
18ºC 22 20.4 19.2 18.4 17.6 /
15ºC 21.32 19.6 18.5
Heating mode Out door condition
Indoor
Conditions
Pressure
12ºC D
11ºC W
0ºC D
-1ºC W
-4ºC D
-6ºC W

Table of Contents