10. Capacity table 
10.1 MSE-07CR 
SUMMER  OUTDOOR TEMPERATURE DRY 
Indoor Conditions
Total capacity kW  2.02  1.92  1.79  1.64  1.51  1.41 
Sensitive capacity kW
1.44  1.39  1.34  1.27  1.20  1.15 
21ºC D 
15ºC W 
Input kW.  0.70  0.76  0.82  0.88  0.95  1.00 
Total capacity kW  2.16  2.07  1.95  1.83  1.71  1.60 
Sensitive capacity kW
1.53  1.48  1.43  1.38  1.34  1.32 
24ºC D 
17ºC W 
Input kW.  0.70  0.77  0.84  0.90  0.97  1.03 
Total capacity kW  2.32  2.27  2.15  1.98  1.81  1.65 
Sensitive capacity kW
1.65  1.62  1.56  1.48  1.41  1.34 
27ºC D 
19ºC W 
Input kW.  0.72  0.79  0.85  0.92  0.99  1.05 
Total capacity kW  2.54  2.45  2.36  2.28  2.18  2.07 
Sensitive capacity kW
1.57  1.59  1.57  1.55  1.53  1.54 
32ºC D 
23ºC W 
Input kW.  0.71  0.79  0.87  0.95  1.03  1.10 
10.2 MSE-07HR 
SUMMER  OUTDOOR TEMPERATURE DRY 
Indoor Conditions
Total capacity kW  2.02  1.92  1.79  1.64  1.51  1.41 
Sensitive capacity kW
1.44  1.39  1.34  1.27  1.20  1.15 
21ºC D 
15ºC W 
Input kW.  0.70  0.76  0.82  0.88  0.95  1.00 
Total capacity kW  2.16  2.07  1.95  1.83  1.71  1.60 
Sensitive capacity kW
1.53  1.48  1.43  1.38  1.34  1.32 
24ºC D 
17ºC W 
Input kW.  0.70  0.77  0.84  0.90  0.97  1.03 
Total capacity kW  2.32  2.27  2.15  1.98  1.81  1.65 
Sensitive capacity kW
1.65  1.62  1.56  1.48  1.41  1.34 
27ºC D 
19ºC W 
Input kW.  0.72  0.79  0.85  0.92  0.99  1.05 
Total capacity kW  2.54  2.45  2.36  2.28  2.18  2.07 
Sensitive capacity kW
1.57  1.59  1.57  1.55  1.53  1.54 
32ºC D 
23ºC W 
Input kW.  0.71  0.79  0.87  0.95  1.03  1.10 
 
WINTER  OUTDOOR CONDITIONS 
Indoor Conditions
7ºC D 
6ºC W 
4ºC D 
3ºC W 
0ºC D 
-1ºC W
1.40  1.17  1.13 
15ºC 
Input kW.  0.97  0.86
0.67  0.62  0.65 
Capacity kW
1.33  1.23  1.09 
18ºC 
Input kW.  0.99  0.86
0.71  0.68  0.68 
Capacity kW
1.27  1.14  1.11 
20ºC 
Input kW.  1.02  0.90
0.71  0.67  0.64 
Capacity kW
1.07  1.15  1.07 
22ºC 
Input kW.  0.94  0.89