Service manual
36
after starting and then judge temperature. Meanwhile other protections are still valid.
* This parameter can be changed from 0 to 3.
11.7.4 Indoor Fan actions at heating mode
Indoor Fan can be set at HIGH/MID/LOW/AUTO by using a remote controller, but Anti-cold wind function
prevails.
Anti-cold wind control function at heating mode (T=indoor exchanger temp.)
11.7.5 Auto wind at heating mode (T=indoor temp.)
0
T-Ts
Room temp. up
Room temp. down
2
Low fan
Med fan
11.7.6 Indoor evaporator high-temperature protection at heating mode
(T=indoor exchanger temp.)