Service manual
- 28 -
9. Capacity table
9.1 MSG-05CR
SUMMER
Cooling mode
Indoor
Conditions
25ºC 30ºC 35ºC 40ºC 45ºC 50ºC
21ºC D
Total capacity kW
1.41
1.33
1.23
1.13
1.06
0.98
15ºC W
Sensitive capacity kW
1.03
0.99
0.93
0.86
0.81
0.76
Input kW. 0.48 0.51 0.53 0.57 0.63 0.65
24ºC D
Total capacity kW
1.53
1.46
1.37
1.29
1.20
1.11
17ºC W
Sensitive capacity kW
1.12
1.09
1.04
0.99
0.93
0.86
Input kW. 0.49 0.52 0.54 0.59 0.65 0.67
27ºC D
Total capacity kW
1.63
1.56
1.47
1.39
1.30
1.19
19ºC W
Sensitive capacity kW
1.24
1.20
1.15
1.09
1.02
0.94
Input kW. 0.51 0.54
0.56
0.60
0.67
0.69
32ºC D
Total capacity kW
1.81
1.74
1.68
1.57
1.43
1.35
23ºC W
Sensitive capacity kW
1.40
1.36
1.32
1.24
1.14
1.09
Input kW. 0.53 0.56 0.58 0.63 0.70 0.72
OUTDOOR TEMPERATURE DRY
9.2 MSG-07CR
SUMMER
Cooling mode
Indoor
Conditions
25ºC 30ºC 35ºC 40ºC 45ºC 50ºC
21ºC D
Total capacity kW
1.97
1.85
1.71
1.58
1.47
1.37
15ºC W
Sensitive capacity kW
1.44
1.38
1.29
1.20
1.13
1.05
Input kW. 0.65 0.69 0.71 0.77 0.86 0.89
24ºC D
Total capacity kW
2.13
2.04
1.90
1.80
1.68
1.55
17ºC W
Sensitive capacity kW
1.57
1.52
1.45
1.38
1.29
1.20
Input kW. 0.67 0.71 0.74 0.80 0.88 0.91
27ºC D
Total capacity kW
2.27
2.17
2.05
1.94
1.81
1.66
19ºC W
Sensitive capacity kW
1.73
1.67
1.60
1.52
1.42
1.32
Input kW. 0.69 0.73
0.76
0.82
0.91
0.94
32ºC D
Total capacity kW
2.53
2.43
2.35
2.18
2.00
1.88
23ºC W
Sensitive capacity kW
1.95
1.89
1.84
1.72
1.60
1.52
Input kW. 0.72 0.76 0.79 0.85 0.95 0.98
OUTDOOR TEMPERATURE DRY
9.3 MSG-07HR
SUMMER
Cooling mode
Indoor
Conditions
25ºC 30ºC 35ºC 40ºC 45ºC 50ºC
21ºC D
Total capacity kW
1.97
1.85
1.71
1.58
1.47
1.37
15ºC W
Sensitive capacity kW
1.44
1.38
1.29
1.20
1.13
1.05
Input kW. 0.65 0.69 0.71 0.77 0.86 0.89
24ºC D
Total capacity kW
2.13
2.04
1.90
1.80
1.68
1.55
17ºC W
Sensitive capacity kW
1.57
1.52
1.45
1.38
1.29
1.20
Input kW. 0.67 0.71 0.74 0.80 0.88 0.91
27ºC D
Total capacity kW
2.27
2.17
2.05
1.94
1.81
1.66
19ºC W
Sensitive capacity kW
1.73
1.67
1.60
1.52
1.42
1.32
Input kW. 0.69 0.73
0.76
0.82
0.91
0.94
32ºC D
Total capacity kW
2.53
2.43
2.35
2.18
2.00
1.88
23ºC W
Sensitive capacity kW
1.95
1.89
1.84
1.72
1.60
1.52
Input kW. 0.72 0.76 0.79 0.85 0.95 0.98
OUTDOOR TEMPERATURE DRY