Troubleshooting
Page 88
Remarks:
Use a multimeter to test the DC voltage between 2 port and 3 port of outdoor unit. The red pin of multimeter
connects with 2 port while the black pin is for 3 port.
When AC is normal running, the voltage is moving alternately as positive values and negative values.
If the outdoor unit has malfunction, the voltage has always been the positive value.
While if the indoor unit has malfunction, the voltage is a fixed value.
Use a multimeter to test the resistance of the reactor which does not connect with capacitor.
The normal value should be around zero ohm. Otherwise, the reactor must have malfunction.