Service manual
23
HEATING OUTDOOR CONDITIONS
Indoor
Conditions
24ºC D
18ºC
W
12ºC D
11ºC
W
7ºC D
6ºC
W
4ºC D
3ºC
W
0ºC D
-1ºC
W
-5ºC D
-6ºC
W
-7ºC D
-8ºC
W
-15ºC D
-16ºC
W
Capacity kW 4.875 6.15 5.72 5.13 4.52 4.21 3.75 3.41
15ºC
Input kW. 1.568 2.07 2.20 2.09 2.01 1.99 1.80 1.76
Capacity kW 4.801 6.09 5.58 5.02 4.39 4.10 3.59 3.27
18ºC
Input kW. 1.6 2.18 2.39 2.20 2.16 2.09 1.83 1.81
Capacity kW 4.684 5.89 4.03 4.90 4.21 3.89 3.37 3.11
20ºC
Input kW. 1.658 2.21
1.11 2.35 2.27 2.15 1.99 1.92
Capacity kW 4.521 5.58 5.39 4.71 4.10 3.70 3.17 2.99
22ºC
Input kW. 1.729 2.28
2.45 2.41 2.40 2.25 2.11 2.00
Capacity kW 4.387 5.37 4.99 4.48 3.90 3.49 3.01 2.71
27ºC
Input kW. 1.804 2.39 2.61 2.55 2.51 2.38 2.27 2.13