03
NOTE
Once the unit has stopped running, do not 
disconnect the power immediately. Wait for at 
least 10 minutes. 
WARNING
Do not touch the air outlet or the horizontal blade 
when operating in the fan swing mode. Your 
ngers may be caught in the unit or the unit may 
be damaged.
NOTE
Do not check or repair the unit on your own. 
Please get relevant professionals to conduct 
any check or repairs.
Do not use substances like gasoline, diluent, 
and chemical dust cloth to wipe the operations 
panel of the controller. This may remove the 
surface layer of the controller. If the unit is dirty, 
immerse a cloth in diluted and neutral detergent, 
squeeze it dry, and then use it to clean the 
panel. Finally, wipe it with a dry cloth.
WARNING
 ● When the fuse melts, do not use any unspec-
ied fuse or other wire to replace the original 
fuse. The use of electrical wires or copper 
wires may cause the unit to malfunction or 
cause a re. 
 ● Do not insert ngers, sticks, or other items 
into the air inlet or outlet. Do not remove the 
fan mesh cover. When the fan rotates at a 
high speed, it may cause bodily injury. 
 ● It is very dangerous to check the unit when 
the fan is rotating. Make sure you turn off the 
main switch before any maintenance work 
begins. 
 ● Do check the supporting and base structure 
of the unit for any damages after a long 
period of use. The unit may drop and cause 
personal injury if there is any damage.
5.2.4 Operating system 
1. Press the "switch" button on the controller.  
Result: The running light turns on and the system starts 
to run. 
2. Repeatedly press the mode selector on the controller 
to select the required operation mode. 
Stop 
Press the "switch" button on the controller again. 
Result: The running light is now off, and the system 
stopped running.
Adjust
Refer to the user manual for the controller on how to 
set the required temperature, fan speed and air ow 
direction.
5.3 Using the Dry Program
5.3.1 About the system operations 
The function in this program uses the minimum 
temperature drop (minimum indoor cooling) to bring 
about a drop in humidity in the room. 
In the drying process, the system automatically 
determines the temperature and fan rotation speed 
(cannot use the user interface to implement the 
settings).
5.3.2 Using the dry program
Start
1. Press the switch button on the controller. 
Result: The running light turns on and the system starts 
to run.
2. Repeatedly press the mode selector on the 
controller.
3. Press the button to adjust the air ow direction (this 
function is not available for all indoor units). 
Stop
4. Press the switch button on the user interface again. 
Result: The running light is now off, and the system 
stopped running.
6 MAINTENANCE AND REPAIR
6.1  Maintenance after Unit has 
been Shut Down for a Long 
Period
For example, in early summer or winter.
 ● Check and remove all objects that may clog the air 
inlets and outlets of the indoor and outdoor units.
 ● Clean the air lter and external shell of the unit. 
Please contact the installation or maintenance 
personnel. The installation/operation manual of the 
indoor unit includes maintenance tips and cleaning 
procedures. Make sure that the clean air lter is 
installed in its original position.
 ● Turn on the main power supply 12 hours before this 
unit is operated in order to ensure that the unit runs 
smoothly. The user interface is displayed once the 
power is turned on.
6.2  Maintenance Before Unit is 
Shut Down for a Long Period
For example, at the end of winter and summer.
 ● Run the indoor unit in the fan mode for about half a 
day to dry the internal parts of the unit.
 ● Turn off the power supply.