Installation
*INSTALLATION*
21
. . .without partition wall
If the appliances are to be installed next
to each other without a partition wall
between them, they will need to be
joined together with the side-by-side in-
stallation kit. In addition, you must in-
stall the side panel heater to prevent
condensation from forming and any re-
sulting damage.
Specifications for the plumbed
water connection
- Connection to the water supply must
comply with the applicable regula-
tions in the country where the appli-
ance is being installed.
All appliances and systems used to
supply water to the refrigeration ap-
pliance must also comply with the
applicable regulations in the respec-
tive country.
- The appliance may only be con-
nected to the plumbed water connec-
tion by qualified technicians.
- The quality of the incoming water
must conform to the requirements for
drinking water in the country where
the refrigeration appliance is being
used.
- Connect the water hose to the fresh
water supply and avoid connection to
a water supply in which the water
might stagnate.
- The appliance is only suitable for
connection to a cold water line.
- The water pressure must be between
29psi and 116psi (2 and 8bar).
- A faucet must be provided between
the water hose and the plumbed wa-
ter connection to ensure that the wa-
ter supply can be cut off if necessary.
- Make sure that the faucet is still ac-
cessible after the appliance has been
installed.