Electrical connection
This tumble dryer is supplied ready for
connection to an a.c. single phase sup-
ply. The machine is supplied with a 2 m
long mains cable with moulded plug.
The appliance should be connected up
only by a qualified electrician, in ac-
cordance with national and local safety
regulations.
For extra safety it is advisable to install
a residual current device (RCD) with
trip current of 30 mA.
The voltage, rated load and fuse rating
are given on the data plate. Please en-
sure that these match the household
mains supply.
Important
The wires in this mains lead are coloured
in accordance with the following code:
Green/yellow = earth
Blue = neutral
Brown = live
As the colours of the wires in the mains
lead of this appliance may not corre-
spond with the coloured markings ident-
ifying the terminals in your plug, pro-
ceed as follows:
The wire which is coloured green and
yellow must be connected to the termi-
nal in the plug which is marked with the
letter E or by the earth symbol z or col-
oured green or green and yellow.
The wire which is coloured blue must
be connected to the terminal which is
marked with the letter N or coloured
black.
The wire which is coloured brown must
be connected to the terminal which is
marked with the letter A or coloured red.
WARNING
THIS APPLIANCE MUST BE
EARTHED