Dispenser pump and Suction pipe
1 = Hose connection socket (suction side)
2 = Hose connection socket (pressure side)
3 = Leakage outlet
4 = Suction inlet opening
5 = Level indicator
When the dispenser container is empty
the pump and the machine will shut off.
PROGRAMME - - - - - - - - - - -
PROGRAMME STOP
DISPENSING SYSTEM FAULT
Dispensing container 1 empty.
The display will indicate that the detergent
dispenser is empty.
The program will continue automatically
once the container has been refilled.
Amount to be dispensed
^
Follow the detergent manufacturer’s guide
-
lines.
Always follow the instructions of the chemi
-
cal manufacturer when using cleaning
agents and special application chemicals.
Only use such chemicals for the purpose
and in the situation specified by the manu
-
facturer to prevent adverse chemical reac
-
tions and material damage.
If in doubt, contact the detergent manu
-
facturer to verify its safety in this machine.
Correct dosage also depends on the visco
-
sity of the liquid detergent. It should stand at
normal room temperature before being used.
Maintenance of the dispensing system
^ Rinse the dispensing system through with
hot water every 2 weeks, or before shutting
the dispenser pumps down for any length
of time, to prevent the system clogging.
^ Rinse out the suction pipes with water.
^ Put the suction pipes in a container with
warm water, 104 - 122 °F (40 - 50 °C) .
^
In Service-Operation program turn on each
pump, until the dispensing system is rin
-
sed through.
^
Check the connection points, hoses and
washers for leaks.