EasyManua.ls Logo

MikroTik LHG 60G

MikroTik LHG 60G
8 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1.
2.
3.
Mount assembled unit to the pole using provided U bolt clamp. Clamping diameter with the provided steel clamp is 35 – 70 mm.
Use the Aim tool to adjust your device. Please see the section LED status.
The device includes a grounding connection (marked ) which you should connect to the grounding installation of the tower or building where the device will
be used. This is to substantially reduce the risk of ESD and lightning damage. Grounding connector included in the package.
Extension slots and ports
One Ethernet port, supporting automatic cross/straight cable correction (Auto MDI/X), so you can use either straight or cross-over cables for
connecting to other network devices.
WiGig, 802.11ad.
Powering
The devices accept powering from the Ethernet port. The Ethernet port accepts PoE input 12-57 V DC (passive and 802.3af/at). A power adapter and a
passive PoE injector are included in the box. When using the PoE injector, make sure to use the "Power + Data" connector to connect to the device, and
the "Data" connector to your PC, router or switch.
Connecting to a POE Adapter:
Connect the Ethernet cable from the device to the POE+DATA port of the POE adapter.
Connect an Ethernet cable from your local network (LAN) to the POE adapter.
Connect the power cord to the adapter, and then plug the power cord into a power outlet.
Maximum power consumption 5 W.
Warning! This equipment should be installed and operated with a minimum distance of 95 cm between the device and your body. Operation of
this equipment in the residential environment could cause radio interference.
The IP rating scale for this device is IP54.
Mounting and configuration of this device should be done by a qualified person.