SPECIFICATIONS
MULTIRANGER PLUS
Power: » 100/115/200/230 V ac ±15%, 50/60 Hz, 15 VA
» optional: » 12 V dc model, 10 to 15 V dc, 15W
» 24 V dc model, 18 to 30 V dc, 15W
» fuse » FU2, Belling Lee, L754, 4000A
HRC, ceramic type, 50mA, 250V
» FU3, Belling Lee, L754, 4000A
HRC, ceramic type, 100mA, 250V
Environment: » location: » indoor / outdoor
» altitude: » 2000 m max
» ambient temp.: » – 20 to 50 °C
» relative humidity: » suitable for outdoor
(Type 4X/NEMA 4X/IP65 enclosure)
» installation category: » II
» pollution degree: » 4
Range: » 0.3 to 15 m (1 to 50 ft)
Accuracy: » 0.25% of range or 6 mm (0.24"), whichever is greater
Resolution: » 0.1% of range or 2 mm (0.08"), whichever is greater
Memory: » EEPROM (non-volatile) no back-up battery required
Display: » Liquid Crystal Display of 4 digits, 18mm (0.7") high
Outputs: transducer drive: » 41 KHz, 400 V peak pulses of 1 msec
max duration at a max
repetition rate of 300 msec
analog: » 0 - 20 or 4 - 20 mA
» max loading: » 350 ohms, return to ground
» 750 ohms, return to –12 V
» resolution: 0.1% of range
» optional mA isolator
relays: » 5 multipurpose relays (for alarms, pump control,...)
» 1 Form "C" SPDT contact per relay, rated 5 A at
250 V ac non-inductive
» adjustable deadband
All relays are certified for use in equipment where the short
circuit capacity of the circuits in which they are connected is
limited by fuses having ratings not exceeding the rating of the relays.
Enclosure: » Type 4X / NEMA 4X / IP65
» 160 mm W x 250 mm H x 82 mm D
(6.3" W x 9.5"H x 3.2"D)
» polycarbonate
98\06\15
PL-513 9