PROGRAMMER
Enclosure: » general purpose
» 67 mm W x 100 mm H x 25mm D
(2.6" W x 4" H x 1" D)
» ABS plastic
Operating Temperature: » – 20 to 50 °C (– 5 to 122 °F)
Power: » 9 V battery (style - ANSI/NEDA 1604)
TRANSDUCER
Refer to associated Transducer manual.
TEMPERATURE SENSOR
Refer to associated Temperature Sensor manual
CURRENT OUTPUT ISOLATOR (Optional, refer to PL-293)
Model: » LIs-1 loop isolator
Input: » 4 - 20 mA dc (from MultiRanger Plus)
Output: » 4 - 20 mA dc into 600 ohm max
Isolation: » 300 V ac continuous
Common Mode Rejection » 100 dB at 60Hz
CABLING
Optional: » RG-62A/U coax
» max distance to electronics: 365 m (1200 ft)
» must be run in grounded metal conduit
Temperature Sensor: » Belden 8760, 2 wire shielded
» max distance to electronics: 365 m (1200 ft)
» can be run with transducer cable
■
PL-443 2 – 2