© 2014 MIMAKI ENGINEERING CO.,LTD. 5.1 P.3
5.1 Changing the Joints
R.1.0
1
2
3
4
5
6
7
Joint change procedure
Work procedures
1. Remove cartridge rear cover from the back panel of the main
unit.
2. Release the knob of fittingφ2, and remove the fitting assy for
UISS.
3. Attach the F seal rubber 300 removed in the procedure 2 and
the new Fitting to the 3-ways fitting.
4. Attach the Cap-outer to the Fitting.
5. Return the cartridge rear cover to the original location, and
affix using the screws.
F seal rubber 300
Fitting
Fitting assy
for UISS
3-ways fitting
Pay attention not to lose the F seal rubber 300.
3-ways fitting
F seal rubber 300
Fitting
Cap-outer
Attach it so that the step of F seal rubber 300 is at
the side of the 3-ways fitting.
Be sure not to insert the fitting obliquely.
Be sure to confirm that the hook of the fitting is
hanging on the 3-way fitting.
INSTALLATION GUIDE > Ink Set > Changing the Joints
Model
CJV300
Issue
2014.09.01
Revised F/W ver.
1.30
Remark
1.0