Gas connections on the heater are leak tested at the factory prior to shipment. A complete gas 
tightness check must be performed due to possible mishandling in shipment or excessive pressure 
being applied to the heater gas connections.
1.Make a soap solution of one part liquid detergent and one part water.
Make sure the control knob on the heater is off and the gas valve on the cylinder is off before 
mixing the soapy solution.
2.Turn on the gas bottle.
3. Apply the soap solution to the gas connections using a soft bristle brush.
Soap bubbles will appear 
if there is a gas leak.
In case of a leak, turn off  
the gas supply. Tighen any 
leaking fittings, then turn the 
gas supply on and re-check.
If there is a leak anywhere 
on the gas cylinder, do not 
use the cylinder. Locate the 
leaking cylinder outdoors 
away from sources of 
ignition, then contact your 
local gas authority or 
cylinder exchange provider 
to arrange disposal. 
Warning:
Do not operate the appliance until all gas leaks have been rectified.
Never leak test while smoking.
+++
Regulator / Cylinder
Hose / Regulator 
Detergent
Gas Leak Test