Gas connections on the heater are leak tested at the factory prior to shipment. A complete gas
tightness check must be performed due to possible mishandling in shipment or excessive pressure
being applied to the heater gas connections.
1.Make a soap solution of one part liquid detergent and one part water.
Make sure the control knob on the heater is off and the gas valve on the cylinder is off before
mixing the soapy solution.
2.Turn on the gas bottle.
3. Apply the soap solution to the gas connections using a soft bristle brush.
Soap bubbles will appear
if there is a gas leak.
In case of a leak, turn off
the gas supply. Tighen any
leaking fittings, then turn the
gas supply on and re-check.
If there is a leak anywhere
on the gas cylinder, do not
use the cylinder. Locate the
leaking cylinder outdoors
away from sources of
ignition, then contact your
local gas authority or
cylinder exchange provider
to arrange disposal.
Warning
Do not operate the appliance until all gas leaks have been rectified.
Never leak test while smoking.
+++
+
+
+
Regulator / Cylinder
Hose / Regulator
Detergent
Gas Leak Test

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mimosa 0151858 and is the answer not in the manual?

Mimosa 0151858 Specifications

General IconGeneral
BrandMimosa
Model0151858
CategoryGas Heater
LanguageEnglish