D
David LevineAug 17, 2025
How to troubleshoot Minnich A-1CL Drill that does not run?
- MMichael DennisAug 18, 2025
If the Minnich Drill isn't getting enough air, especially when using multiple drill units, try switching the airline with a drill that's working. If the drill then runs, inspect the air control valve. If the valve is functional, check the drill itself. Ensure the valves on both the air compressor and drill unit are fully open. The compressor should provide 100 SCFM per drill and 110 PSI at the drill manifold when using large drills. Also, verify all fittings are properly connected and not leaking.