D-52
(4) Cleaning of the Comb Electrode
(5) Removal of the Image Transfer/Paper Separator Coronas
(6) Cleaning of the Image Transfer Corona Wire
1. Clean Comb Electrode using the PC Drum Charge
Corona Cleaning Lever.
1156D072AA
1. Swing down the Front Door.
2. Pull out the Transfer/Paper Separator Coronas.
1134D062AA
1. Swing down the Front Door.
2. Clean Image Transfer Corona Wire using the
Image Transfer Corona Wire Cleaning Lever.
1136D198AA
NOTE
If the Image Transfer Corona Wire is seriously contam
-
inated, dampen a soft cloth with alcohol, hold it with a
pair of tweezers, and wipe the wire gently in one direc-
tion-from the hook end to the spring end.