Operating indicators
INDICATOR STATE FUNCTION SOLUTION
1.Water
OFF No leaks N/A
Indicator N°1 & 6
flashing
Leak
(only if option activated)
Turn off water supply.
General device inspection.
ON
Lack of water
Check that the water cooler is well connected to
water supply, That water pressure is set at 3 bars
+/- 0,5 bars.
Check that the Watersafe® antileak system is
well connected.
Fixed ON + Indicator
N°6 fixed ON
Safety shutdown : the dis-
tribution ran for more than
5min without interruption
Disconnect the water cooler. Wait for 1 min and
reconnect it.
2.UV
OFF UV lamp is working
Flashing UV lamp will be off soon
Plan the replacement of ToBeSure® disinfection
system.
ON UV lamp is not working
Change the ToBeSure® disinfection system.
3.Drip-tray
OFF OK
ON
Drip-tray or dirp-tray
container is full
Empty the drip-tray / container.
4.Filter
OFF OK
ON Used filter
Maintenance & replacement of the filter.
Do not forget to Reset (see page ...).
5.CO2
OFF OK
Flashing + Indicator N°6
ON
Pump safety
The pump has been running continuously for
more than 5 minutes causing the fountain to shut
down. Disconnect the device, wait for 1min and
reconnect it.
ON CO2 cartrigdge empty
Remplace the cartridge.
6. Maintenance
OFF OK
Fixed ON Keyboard connection loss
Call a qualified technician for diagnosis and
maintenance.