26
TROUBLESHOOTING
The appliance has a self diagnosis
system to identify a number of
malfunctions.
Please contact the Service Centre.
Empty the internal safety tank,
following the instructions in the
"End of season operations"
paragraph.
Wait
The appliance does not power on.
Plug into the mains.
Wait 30 minutes, if the problem
persists, please contact the Service
Center.
There is no current.
It is not plugged into the mains.
Position the air exhaust hose
correctly, keeping it as short and
free of curves as possible to avoid
bottlenecks.
The appliance works for a short
time only.
Check and remove any obstacles
obstructing air discharge.
Here are bend in the air exhaust
hose.
Something is preventing the air
from being discharged.
The internal safety device has
tripped.
Close doors, windows, and
curtains, bearing in the mind the
“tips for correct use” given above.
The appliance works, but does not
cool the room
Eliminate the heat sources.
Fit the air exhaust hose in the
housing at the back of the
appliance.
Windows, doors, and/ or curtains
open.
There are heat sources in the
room (oven, hairdryer, etc)
The air exhaust hose is detaches
from the appliance.
--
The technical specication of the
appliance is not adequate for the
room in which it is located.
Probe Failure (Sensor Damaged)
Air lter clogged.
Clean the lter as described
above.
Wait. This delay is part of the
normal operation.
The internal compressor safety
device prevents the appliance
from being restarted until 3
minutes have elapsed since it was
last turned o.
During operation there is an
unpleasant smell in the room.
The appliance does not operate
for about 3 minutes after
restarting it.
Problem Cause of Issue Solution