Fault Conrmation and Analysis
n If problems persist after performing the tests below, please stop the air conditioner and
contact our service centre nearest to you to get help.
Fault Fault analysis
Air conditioner does not operate at all. u Is there a power failure?
Is the unit unplugged?
Is the power fuse or switch off?
Is the timer set correctly?
Remote controller does not display
u If the operation modes are changed too
any information. frequently the remote controller may lose function.
If remote controller display is unclear or displays all
symbols, please change the batteries or reset.
Remove and replace batteries.
Cooling and heating efciency is poor.
u Is the temperature set to the correct level?
Are the lters clean
?
Are doors and windows closed
?
Indoor unit fan stops for about 10 minutes
u This is normal. The unit is defrosting the outdoor
during heating. unit coil. It should complete this process in about
10 minutes at most. (Freezing occurs when
outdoor temperature is low and humidity is high)
You can hear the sound of running water
u This is the sound of expanding refrigerant inside
the air conditioner.
Sound of accumulated water dropping on the
heat-exchanger.
The sound of melting frost on heat-exchanger.
Performance Parameters
Model
MSS10 - 1HP MSS15 - 1.5HP
indoor outdoor indoor outdoor
Function heat pump type heat pump type
Power 230V~, 50Hz 230V~, 50Hz
Rated cooling/heating capacity (W) 2000/2400 3500/4000
Standard input power (W) 750(cool)/730(heat) 1300(cool)/1380(heat)
Standard input current (A) 3.5(cool)/3.4(heat) 6.2(cool)/6.6(heat)
Air ow volume (m³/h) 300 450
Dehumidifying capacity (L/h) 1.0 1.6
Protection I
Water-proof IP20(INDOOR) IP24(OUTDOOR)
Climate type T1
Refrigerant (R22) charge amount (g) 560 1120
Noise dB (A) 31 45 40 48
Net weight (Kg) 10 26 11 37
Dimension (mm) WxHxD 800x183x290 665x295x500 800x183x290 830x310x500
NOTE 1. The indicated noise value is from laboratory test done before leaving the factory.
2. The rated cooling capacity and rated heating capacity value is tested under following conditions.
cooling operation indoor 27˚C (DB) 19˚C (WB) outdoor 35˚C (DB) 24˚C (WB)
heating operation indoor 20˚C (DB) 15˚C (WB) outdoor 7˚C (DB) 6˚C (DB)
3. All of the above information may be changed without notice. These are the latest and
accurate specications on the name plate of your air conditioner.
4. Working temperature range:
Maximum cooling Minimum cooling Maximum cooling Minimum cooling
Indoor side (DB/WB (˚C) 32/23 21/15 27/-- 20/--
Outdoor side DB/WB (˚C) 43/26 21/15 24/18 -5/-6
5. If air conditioner working voltage exceeds 230V±10% it may operate abnormally.
6. Wiring diagrams of air conditioner (indoor unit/outdoor unit) are attached to the unit.
7. If the power cable or connecting cable is damaged, it must be replaced by its service agent