Remote Command Sequence: ?ATTnn
Unit Response: ?ATTnnTttt
ATT: Attenuation indicator
nn: Two digit ASCII numeric characters,
Indicating converter. “00” through “12”.
T: Attenuation parameter indicator
ttt: Three digit ASCII numeric characters,
MSD transmitted first, LSD last indicating attenuation in tenths of a dB.
4.2.6 INTERNAL CALENDAR/CLOCK = CLK
The SET command requires a twenty-character parameter that sets the date and time of
the internal calendar/clock.
Remote Command Sequence: $CLKYyyyyMmmDddHhhNnnSss
Response: $CLK
The QUERY command requires no parameters.
Remote Command Sequence: ?CLK
Response: ?CLKYyyyyMmmDddHhhNnnSss
Y: Year indicator
yyyy: Year, 4-digit ASCII numeric characters, MSD transmitted first, LSD last.
M: Month indicator
mm: Month, 2-digit ASCII numeric characters
D: Day indicator
dd: Day, 2-digit ASCII numeric characters
H: Hour indicator
hh: Hour, 2-digit ASCII numeric characters
N: Minute indicator
nn: Minute, 2-digit ASCII numeric characters
S: Second indicator
ss: Second, 2-digit ASCII numeric characters
4.2.7 SET ALL ETHERNET PARMETERS = EAD
The SET command requires three 12-digit parameters indicating the Ethernet IP
address, Ethernet gateway and the Ethernet subnet mask of the NSU control unit.
Remote Command Sequence: $EADIiiiiiiiiiiiiGggggggggggggSssssssssssss
Unit Response: $EAD