Remote Command Sequence: ?PRInn
Response: ?PRInnPpp
PRI: Redundancy chain priority indicator.
nn: Two-digit ASCII numeric characters “01” to “12” indicating chain position
P: Priority indicator.
pp: Two-digit ASCII numeric characters indicating priority,
“01” through “12”, “01” is the most critical.
4.2.17 UNIT REDUNDANCY MODE = RED
The SET command requires a one-digit parameter indicating the redundancy mode
selection Manual or Automatic.
Remote Command Sequence: $REDr
Response: $RED
The QUERY command requires no parameters.
Remote Command Sequence: ?RED
Response: ?REDr
RED: Redundancy mode indicator.
r: "0" through "1" ASCII numeric character
0 = Manual
1 = Automatic
4.2.18 SERIAL NUMBER = SER
The QUERY command requires no parameters.
Remote Command Sequence: ?SER
Response: ?SERnnnnnnnnnn
nnnnnnnnnn: Ten-character unit serial number.
4.2.19 SLOPE = SLP
The SET command requires two parameters, one which is two digits in length
representing the redundancy chain position and one parameter which is a two-digit
parameter representing the slope in dB.
Refer to Section 4 for converter settings operation.
Remote Command Sequence: $SLPnnSsgg
Response: $SLP
The QUERY command requires a two-digit parameter indicating chain position.
Remote Command Sequence: ?SLPnn
Response: ?SLPnnSsgg