EasyManua.ls Logo

Mitox 260B - Page 20

Mitox 260B
26 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
260B Blower / 280BV Blower Vacuum
20
Original Instructions Version July 12
Every 10/15 Hours Use
1.Usethesparkplugwrenchtoremovethespark
plug(turncounter-clockwisetoremove).
2. Clean and adjust the spark plug gap to
0.6~0.7mm. Replace any damaged or visibly worn
plugwithachampionRCJ6Yorequivalent.
3.Installthesparkplugnger-tightinthecylinder
head, and then tighten it rmly with the spark plug
wrench.Ifatorquewrenchisavailable,torquethe
sparkplugto148-165inchpounds.
Every 50 Hours Use (MOREFREQUENTLYIFYOUNOTEREDUCEDPERFORMANCE)
INSPECTIONInspecttheentiremachineand
tubes for damage, including loose or missing
components, and repair as necessary.
SPARK PLUG Replace the spark plug with a
championL9T(LD),gappedto(0.6~0.7)mm.
FUELFILTERUseawirehooktoextractthefuellter
from inside the fuel tank, and then remove and
wash the lter element in clean fuel.
Before reinstalling the lter, inspect the condition
of the fuel line. If damage or deterioration is noted,
the vacuum should be removed from service until
it can be inspected by a trained service technician.
COOLINGSYSTEMRemovetheenginecover(asdescribedunder“SparkArrestor”),anduseawoodorplastic
scraper and a soft brush to remove dirt and debris from the cylinder ns and crankcase.