INDUSTRIAL AUTOMATION
MITSUBISHI ELECTRI
C
MITSUBISHI ELECTRI
C
FR-F800
Inverter
Instruction Manual
FR-F820-00046(0.75K) to 04750(110K)(-E)
FR-F840-00023(0.75K) to 06830(315K)(-E)
FR-F842-07700(355K) to 12120(560K)(-E)
Art. no.: 292550
01 06 2017
Version C
Version check

Table of Contents

Other manuals for Mitsubishi Electric FR-F840-00250

Questions and Answers:

Mitsubishi Electric FR-F840-00250 Specifications

General IconGeneral
ModelFR-F840-00250
CategoryInverter
ManufacturerMitsubishi Electric
SeriesFR-F800
Input Phase3-phase
Rated Output Current52 A
Frequency Range50/60Hz
Cooling MethodForced air cooling
Enclosure RatingIP20
Protection StructureIP20
Operating Temperature-10 to +50°C
Storage Temperature-20 to +65°C
Weight4.0 kg
Control MethodV/F control, Vector control
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Ground fault, Stall prevention
Communication InterfaceRS-485
Ambient Humidity5-95% RH (non-condensing)
Vibration Resistance5.9 m/s2

Summary

Installation and wiring

Installation of the inverter and enclosure design

Details on determining enclosure structure, size, and device layout for optimal inverter performance.

Precautions for use of the inverter

Electro-magnetic interference (EMI) and leakage currents

Discusses EMI and leakage currents, including countermeasures.

Checklist before starting operation

Provides a checklist of critical points to verify before starting inverter operation.

Failsafe system which uses the inverter

Explains how to use inverter status output signals to provide an interlock for detecting inverter failure.

Basic operation

Basic operation procedure (PU operation)

Provides a step-by-step guide for basic operation using the PU.

Basic operation procedure (External operation)

Details basic operation procedures when using external signals.

Parameters

Parameter List

Provides a comprehensive list of inverter parameters, categorized by function and control method.

Control method

Explains the available control methods: V/F control, Advanced magnetic flux vector control, and PM motor control.

Motor constant parameters

Details parameters related to motor constants for induction and IPM motors.

(A) Application parameters

Covers parameters related to specific application settings like electronic bypass and PID control.

Protective functions

Inverter fault and alarm indications

Explains the different types of faults and alarms displayed by the inverter.

Causes and corrective actions

Details common causes for inverter faults, warnings, and alarms, with corresponding corrective actions.

Check first when you have a trouble

Provides a checklist for initial troubleshooting of common inverter issues.

Precautions for maintenance and inspection

Inspection item

Lists daily and periodic inspection items to prevent inverter faults.

Specifications

Inverter rating

Provides specifications for the inverter, including voltage class, capacity, and current ratings.

Motor rating

Details the specifications for various premium high-efficiency IPM motors.