8 SFC PROGRAM
8.2 Structure
91
8
Ex.
Example of jump sequence that cannot be specified in the simultaneous branch
Precautions
Under the following conditions, a step cannot be specified as the destination of jump sequence.
When a step immediately before the preceding transition is specified
When current step is specified (when "FX3 compatible transition operation mode setting" is set to "Enable", a step can be
specified.)
Jump sequence to another branch within a
simultaneous branch
Jump sequence for exiting from a simultaneous
branch
Jump sequence to a simultaneous branch from
outside a simultaneous branch
(1) A simultaneous convergence cannot be performed.
(1)
(1)