4 SAFETY FB SPECIFICATIONS
4.6 M+SF_ESTOP_R
39
4
FB details
o_bS_EStop_Out output signal is set to OFF as soon as i_bS_EStopIn input is set to OFF. o_bS_EStop_Out output signal is
set to ON only if i_bS_EStopIn input is set to ON and a reset occurs. If the automatic reset is selected for i_bS_StartReset and
i_bS_AutoReset, reset is not required.
State diagram
State transition of M+SF_ESTOP_R
The signal (o_bS_EStop_Out) may only control the process directly if this does not adversely affect the safety function. In this regard, validate the entire path of
the safety function, including the startup behavior of the process to be controlled.
Note: The transition from any state to the Idle state due to i_bActivate=OFF is not shown. However these transitions have the highest priority (0).
WARNING
o_bReady=OFF
o_bReady=ON
0
3
3
1
1
1
2
3
1
2
2
1
1
1
1
1
2
Idle
0000H
i_bActivate=ON
i_bActivate=OFF
init
8001H
i_bS_StartReset=OFF
Reset Error 1
C001H
Reset Error 2
C002H
Wait for
S_EStopIn 2
8004H
Wait for
S_EStopIn 1
8002H
i_bS_EStopIn
=ON
i_bReset
=OFF
Wait for
Reset 1
8003H
i_bS_EStopIn=ON
AND
i_bS_AutoReset=ON
(R_TRIG
at i_bReset)=ON
Wait for
Reset 2
8005H
(R_TRIG at i_bReset)=ON
OR i_bS_AutoReset=ON
Safety Output
enabled
8000H
o_bS_EStop_Out=OFF
o_bS_EStop_Out=ON
i_bS_EStopIn =OFF
i_bS_StartReset=ON AND
i_bS_EStopIn=OFF
i_bS_EStopIn=ON AND
i_bS_StartReset=ON
i_bS_EStopIn
=OFF
i_bReset=OFF
i_bReset=ON AND
(R_TRIG at i_bReset)=OFF
i_bS_EStopIn=ON
AND
i_bS_AutoReset=OFF
i_bS_EStopIn
=OFF
i_bReset=ON AND
(R_TRIG at i_bReset)=OFF