5 - 144
MELSEC-Q
5 DATA USED FOR POSITIONING CONTROL
Setting item Setting details
When changing the acceleration time during a speed change, use this data item
to specify a new acceleration time.
Cd.10
setting range (unit)
0 to 8388608 (ms)
Cd.10
New acceleration time value
When changing the deceleration time during a speed change, use this data item
to specify a new deceleration time.
Cd.11
setting range (unit)
0 to 8388608 (ms)
Cd.11
New deceleration time value
Cd.12
Acceleration/deceleration time
change during speed change,
enable/disable selection
Enables or disables modifications to the acceleration/deceleration time during a
speed change.