14 - 11 
MELSEC-Q
 
14   DEDICATED INSTRUCTIONS 
 
14.5 PFWRT 
These dedicated instructions are used to write the QD75 parameters, positioning data 
and block start data to the flash ROM. 
 
Usable device 
Internal device 
MELSECNET/10 
direct J
\  
Constant 
Setting 
data 
Bit Word 
File  
register 
Bit Word 
Special  
module  
U
\G  
Index 
register  
Zn 
K, H, $ 
Others 
(S)
 
– 
 
– – – 
(D) 
   
– – – – 
 
[Instruction symbol] [Execution condition]
PFWRT
ZP.PFWRT "Un" (S) (D)
 
 
[Setting data] 
 
Setting data  Setting details 
Setting side 
(
1) 
Data type 
"Un" 
QD75 head I/O number 
(00 to FE: High-order two digits of I/O number expressed in three digits) 
User  BIN 16 bits 
(S)  Head number of a device in which control data is stored  –  Device 
(D) 
Head number of a bit device which turns ON the operation by one scan at the 
time of completion of the instruction. 
If the instruction is completed abnormally, ((D) + 1) will also be turned ON. 
System Bit 
Note) The file register of each of the local device and the program cannot be used as a device for setting data. 
 
[Control data] 
 
Device Item  Setting data 
Setting 
Range 
Setting side 
(
1) 
(S)+0 System area  –  –  – 
(S)+1 Complete status 
The state at the time of completion is stored. 
 0  :  Normal completion 
  Other than 0 :  Abnormal completion (error code)(
2) 
– System 
1:  The data on the setting side is as follows. 
  • User  :  Data before the execution of dedicated instructions is stored by user. 
  • System:  Data after the execution of dedicated instruction is stored by PLC CPU. 
2:  Refer to Section 15.2 for error codes at abnormal completion.